Connection of motor encoder and external encoder
Installation
External
encoders
You can connect the following motor encoders at X14 on the MOVIDRIVE
®
compact
units:
•
MCV/MCS4_A
– DC 5 V TTL sensors with signal level to RS422
•
MCH4_A
– Hiperface
®
encoder
– High-resolution sin/cos encoders with signal voltage AC 1 V
SS
– DC 5 V TTL sensors with signal level to RS422
Voltage supply
Connect encoders with DC 12/24 V voltage supply (max. 180 mA) directly at X14. These
encoders are then powered by the inverter.
Connect encoders with a DC 5 V voltage supply via the "DC 5 V encoder power supply
type DWI11A" option (part number 822 759 4).
DC 5 V TTL
sensor
DC 5 V TTL sensors from SEW-EURODRIVE are available with DC 24 V and DC 5 V
voltage supply.
DC 24 V voltage
supply
Connection to MCV/MCS4_A:
Cut off the violet conductor (VT) of the cable at the encoder end.
Part number of the prefabricated cable:
•
Fixed installation only:
815 354 X
59859AXX
Figure 129: Connect the TTL sensor to MCV/MCS4_A as an external encoder
1
6
2
7
3
8
9
5
4
YE
GN
RD
BU
PK
GY
WH
BN
VT
5
1
9
6
MOVIDRIVE
X14:
®
max. 100 m
A (K1)
(
)
B (K2)
(
)
C (K0)
(
)
UB
A K1
B K2
C K0
⊥
ES1R / ES2R / EV1R
UB
K1 K2 K0
⊥
K1 K2 K0
쵰
쵰
UB
A B C
⊥
A B C
✂
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...
Page 432: ......