General startup instructions
Startup
10
Startup
10.1
General startup instructions
Prerequisites
The drive must be configured correctly to ensure that startup is successful. Refer to the
MOVIDRIVE
®
compact
system manual (sections 4 and 5) for detailed project planning
instructions and an explanation of the parameters.
VFC operating
modes without
speed control
The factory settings of MOVIDRIVE
®
compact
drive inverters are set to be taken into
operation with the SEW motor adapted to the correct power level (MC_4_A...-5_3:4-pole
and rated voltage 3
×
AC 400 V / 50 Hz or MC_4_A...-2_3: 4-pole and rated voltage
3
×
AC 230 V / 60 Hz). The motor can be connected and the drive started immediately
in accordance with the section "Starting the motor" (
→
Inverter/motor
combinations
The following tables indicate which inverter/motor combinations this applies to.
AC 400/500 V
units
DANGER!
Uncovered power connections.
Severe or fatal injuries from electric shock.
•
Install the touch guard according to the regulations.
•
Never start the unit if the touch guard is not installed.
NOTE
Startup in accordance with this section is necessary for the VFC operating modes with
speed control, all CFC operating modes and SERVO operating modes. The startup
functions described in this section are used to set the inverter so it is optimally adapted
to the connected motor and to the given boundary conditions.
MOVIDRIVE
®
compact
MCF4_A
or MCV/MCH4_A in VFC operating mode
SEW motor
0015-5A3-4
DT90L4
0022-5A3-4
DV100M4
0030-5A3-4
DV100L4
0040-5A3-4
DV112M4
0055-5A3-4
DV132S4
0075-5A3-4
DV132M4
0110-5A3-4
DV160M4
0150-503-4
DV160L4
0220-503-4
DV180L4
0300-503-4
DV200L4
0370-503-4
DV225S4
0450-503-4
DV225M4
0550-503-4
DV250M4
0750-503-4
DV280S4
0
0
I