180
System Manual – MOVIDRIVE® compact Drive Inverters
3
Operating modes
Parameters
CFC & IPOS
CFC & IPOS (only with MCV, MCH) in parameter set 1 only.
Must be set if IPOS
plus®
positioning commands are to be processed. Refer to the
"IPOS
plus®
Positioning and Sequence Control System" manual for detailed descriptions
of IPOS
plus®
. This manual can be obtained from SEW-EURODRIVE.
SERVO
SERVO (only with MCS, MCH) in parameter set 1 only.
The SERVO operating mode allows for operating a permanent-field synchronous motor
(servomotor). The motor must be equipped with a resolver or a Hiperface
®
encoder.
The SHELL startup function requires the motor type to be entered (SEW motor). Startup
cannot be performed with the DBG11B keypad in SERVO mode. The following param-
eters are preset (parameter set 1):
SERVO always requires to startup the speed controller.
Setting the parameter P820 4-quadrant operation 1 will be ignored; 4-quadrant opera-
tion is always active.
Settings after the startup function
I
max
(inverter) = Max. motor current at standstill
Torque limit
The value of the motor torque can be limited. The maximum value
is determined by the motor type. P303 Current limit 1. Do not
change!
Rated motor speed (2000 1/min, 3000 1/min, 4500 1/min)
0 1/min
MOTOR & REGENERATIVE
0.1 s
UNIPOL./FIX.SETPOINT
TERMINALS
ON
Setting in accordance with specified motor data
Settings after the startup function of the speed controller
Setting in accordance with specified data
P201 Time constant n-controller
P202 Gain acceleration feedforward
P204 Filter speed actual value
P203 Filter acceleration feedforward
Position controller gain for the hold control function
Position controller gain for IPOS
plus®
(positioning mode)
Setting in accordance with specified data
P6..
P60.
P600