System Manual – MOVIDRIVE® compact Drive Inverters
359
10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Starting the inverter with PROFIBUS-DP (MC_41A)
Startup
Additional code
The additional code contains SEW-specific return codes for incorrect parameter setting
of the drive inverter. They are returned to the master under Error Class 8 = "Other Error".
The following table shows all possible codings for the additional code.
Error class: 8 = "Other error"
Special return
codes (special
cases)
Errors in parameter settings, which cannot be identified either automatically by the
application layer of the fieldbus system or by the system software of the drive inverter,
are treated as special cases. The possible causes for such errors are as follows:
•
Incorrect coding of a service via parameter channel
•
Incorrect length specification of a service via parameter channel
•
Internal communication error
Incorrect service
code in the para-
meter channel
Incorrect code was specified in the management byte or reserved byte during parameter
setting via the parameter channel. The following table shows the return code for this
special case.
Correcting the error:
Check bits 0 and 1 in the parameter channel.
Add. code
high (hex)
Add. code low
(hex)
Meaning
00
00
No error
00
10
Illegal parameter index
00
11
Function / parameter not implemented
00
12
Read access only
00
13
Parameter lock is active
00
14
Factory setting is active
00
15
Value for parameter too large
00
16
Value for parameter too small
00
17
Required option card missing for this function/parameter
00
18
Error in system software
00
19
Parameter access via RS-485 process interface on X13 only
00
1A
Parameter access via RS-485 diagnostic interface only
00
1B
Parameter is access-protected
00
1C
Controller inhibit required
00
1D
Invalid value for parameter
00
1E
Factory setting was activated
00
1F
Parameter was not saved in EEPROM
00
20
Parameter cannot be changed with enabled output stage
Code (dec)
Meaning
Error class:
5
Service
Error code:
5
Illegal parameter
Add. code high:
0
-
Add. code low:
0
-
0
0
I