System Manual – MOVIDRIVE® compact Drive Inverters
107
3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Overview of parameters
Parameters
Response MOTOR OVERLOAD
EMERG. STOP/FAULT
Response RS485 TIMEOUT
RAPID STOP/WARNG
LAG ERROR response
EMERG. STOP/FAULT
Response TF SIGNAL
NO RESPONSE
Response SBus TIMEOUT
EMERG. STOP/FAULT
Response SW LIMIT SWITCH
EMERG. STOP/FAULT
Reset behavior
Manual reset
YES / NO
Auto reset
ON / OFF
Restart time
1 ... 3 ... 30 s
Scaling actual speed value
Scaling factor numerator
1 ... 65 535
Scaling factor denominator
1 ... 65 535
User-defined unit
1/min
Modulation
PWM frequency 1 / 2 VFC
4 / 8 / 12 / 16 kHz
PWM fix 1/2
ON / OFF
PWM CFC
4 / 8 / 16 kHz
Process data description
Setpoint description PO1
CONTROL WORD 1
Setpoint description PO2
SPEED
Setpoint description PO3
NO FUNCTION
Actual value description PI1
STATUS WORD 1
Actual value description PI2
SPEED
Actual value description PI3
OUTPUT CURRENT
PO data enable
ON / OFF
Serial communication SBus
Manual operation
ON / OFF (only in DBG11B)
888
Synchronization time
1 ... 5 ... 10 ms
IPOS parameters
IPOS Reference travel
Reference offset
–(2
31
–1) ... 0 ... 2
31
–1 inc.
Reference speed 1
0 ... 200 ... 5000 1/min
Reference speed 2
0 ... 50 ... 5000 1/min
Reference travel type
0 ... 8
Reference travel to zero pulse
YES / NO
Hiperface
®
offset X15
–(2
31
–1) ... 0 ... 2
31
–1 inc.
IPOS travel parameters
Gain X controller
0.1 ... 0.5 ... 32
Positioning ramp 1
0.01 ... 1 ... 20 s
Positioning ramp 2
0.01 ... 1 ... 20 s
Positioning speed CW
0 ... 1500 ... 5000 1/min
Positioning speed CCW
0 ... 1500 ... 5000 1/min
Speed feedforward
–199.99 ... 0 ... 100 ... 199.99 %
Ramp type
LINEAR / SINE / SQUARE / BUS RAMP / JERK-LIMITED
/ ELECTRONIC CAM / SYNCHRONOUS OPERATION
Ramp mode
MODE 1 / MODE 2
P6..
P60.
P600
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...
Page 432: ......