342
System Manual – MOVIDRIVE® compact Drive Inverters
10
Complete parameter list
Startup
10.6
Complete parameter list
General
information
•
The parameters of the quick menu are marked by a "/" (= display on the DBG11B
keypad).
•
The factory setting for the parameter is highlighted in bold.
Par.
Name
Value range
Par.
Name
Value range
DISPLAY VALUES
07_
Unit data
00_
Process values
070
Unit type
000
Speed
–5000...0...5000 1/min
071
Rated unit current
001/
User display
[Text]
076
Firmware basic unit
002
Frequency
0... 1100 Hz
077
Technology function
003
Actual position
–2
31
–1...0...2
31
–1 inc
08_
Error memory
004
Output current
0...200 % I
N
080/
Error t-0
005
Active current
–200...0...200 % I
N
081
Error t-1
006/
Motor utilization 1
0...200 %
082
Error t-2
007
Motor utilization 2
0...200 %
083
Error t-3
008
DC link voltage
0...1000 V
09_
Bus diagnostics
009
Output current
A
090
PD configuration
01_
Status displays
091
Fieldbus type
010
Inverter status
092
Fieldbus baud rate
011
Operating state
093
Fieldbus address
012
Error status
094
PO1 Setpoint
013
Current parameter set
1/2
095
PO2 Setpoint
014
Heat sink temperature
–20...0...100 °C
096
PO3 Setpoint
015
Hours of operation
0...25000 h
097
PI1 Actual value
016
Enable hours
0...25000 h
098
PI2 Actual value
017
Work
kWh
099
PI3 Actual value
02_
Analog setpoints
020
Analog input AI1
–10...0...10 V
021
Analog input AI2
–10...0...10 V
022
External current limit
0...100 %
03_
Binary inputs basic unit
030
Binary input DIØØ
/CONTROL.INHIBIT
031
Binary input DIØ1
032
Binary input DIØ2
033
Binary input DIØ3
034
Binary input DIØ4
035
Binary input DIØ5
036/
Status of binary inputs on basic unit
05_
Binary outputs basic unit
050
Binary output DBØØ
/BRAKE
051
Binary output DOØ1
052
Binary output DOØ2
053/
Status of binary outputs on basic unit
0
0
I
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...
Page 432: ......