System Manual – MOVIDRIVE® compact Drive Inverters
329
10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Preliminary work and resources
Startup
10.2
Preliminary work and resources
•
Check the installation.
•
Performing startup with the DBG11B keypad:
Plug the DBG11B keypad into the TERMINAL slot.
•
For startup with a PC and MOVITOOLS
®
:
Plug the USS21A or USB11A option into the TERMINAL slot. Connect the
USS21A/USB11A option to the PC with an interface cable (RS232). If not already
available, install MOVITOOLS
®
on the PC. Start MOVITOOLS
®
.
•
Switch on the mains voltage and, if applicable, the DC 24 V supply voltage.
If you are using the DBG11B keypad, the following message is displayed for approx-
imately 13 s.
•
Check that the default parameter settings are correct (e.g. factory setting).
•
Check the terminal assignment that has been set (
→
P60_).
DANGER!
Risk of crushing if the motor starts up unintentionally.
Severe or fatal injuries.
•
Prevent unintentional start up of the motor by implementing the following measures:
– For MCF/MCV/MCS4_A: Connect terminal X10:9 "/CONTROLLER INHIBIT"
with X10:15 "DCOM".
– For MCH4_A: Disconnect the electronics terminal block X11.
•
Furthermore, additional safety precautions must be taken depending on the
application to avoid injury to people and damage to machinery.
SELFTEST
MOVIDRIVE
NOTE
A group of parameter values is changed automatically at startup. The description of
parameter P700 "Operating modes" explains which parameters are affected by this
step. Refer to the MOVIDRIVE
®
compact system manual, section 4 "Parameters", for
the parameter description.