System Manual – MOVIDRIVE® compact Drive Inverters
83
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Output choke HD...
Technical Data and Dimension Drawings
2.17
Output choke HD...
•
For suppression of interference from the unshielded motor cable. We recommend
routing the motor cable through the output choke with 5 loops. You can use less than
5 loops if the cable has a large diameter. Instead, connect 2 or 3 output chokes in
series. If you use 4 loops, connect two output chokes in series, and if you use 3 loops,
connect three output chokes.
•
The output chokes are assigned to the motor cables using the cable cross sections.
Consequently, there is no separate assignment table for AC 230 V units.
Dimension
drawing for HD...
All dimensions in mm:
Output choke type
HD001
1)
HD002
HD003
Part number
813 325 5
813 557 6
813 558 4
Max. power loss
P
Vmax
15 W
8 W
30 W
For cable cross sections/connections/
tightening torque
1.5...16 mm
2
(AWG 16...6)
≤
1.5 mm
2
(AWG 16)
≥
16 mm
2
(AWG 6)
1) The HD... output choke is not a UL/cUL-relevant component.
58419AXX
d
a
b
c
C
A
B
HD001
HD002
HD003
Output choke
type
Main dimensions
Mounting dimensions
Inside
∅
Hole
dimension
Weight
A
B
C
a
b
d
c
kg
HD001
121
64
131
80
50
50
5.8
0.5
HD002
66
49
73
44
38
23
0.2
HD003
170
64
185
120
50
88
7.0
1.1
P
i
f
kVA
Hz
n
Summary of Contents for MOVIDRIVE compact MCH41A