System Manual – MOVIDRIVE® compact Drive Inverters
189
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Motor selection for asynchronous AC motors (VFC)
Project Planning
Motor selection in connection type delta/star (AC 230/400 V / 50 Hz)
Motors for AC 380 V / 60 Hz can also be allocated on the basis of this selection table.
P
max
[kW] for operation on MOVIDRIVE
®
compact
MCF/MCV/MCH 4_A...-5_3 (AC 400/500 V units)
Connection
댴
/ AC 400 V
1)
1) Also applies to motors with rated voltage 460 V or 500 V and for motors 400/690 V with
∆
connection.
∆
/ AC 230 V
2)
2) Also applies to motors with 266 V or 290 V rated voltage.
Cooling
Own
Forced
Own
Forced
f
min
- f
max
[Hz]
10 - 50
6 - 60
5 - 70 / 5.5 - 80
≤
2.5 - 50 /
≤
3 - 60
3)
3) The following applies to MCF, MCV and MCH without speed control: f
min
= 0.5 Hz
9 - 87
≤
2.5 - 87
n
min
- n
max
[1/min]
300 - 1500
180 - 1800
150 - 2100 / 165 - 2400
≤
75 - 1500 /
≤
90 - 1800
270 -
2610
≤
75 - 2610
Setting range
1:5
1:10
1:15
≥
1:20
1:10
≥
1:20
Motor type
Rated power P
n
[kW]
P = P
reduced
P = P
n
P = P
increased
4)
4) P
increased
means that the motor is operated at the power of the next larger motor (one frame size), rather than with
√
3-fold power.
[kW]
MCF/MCV/MCH
5)
4_A...-5_3
5) The units listed here permit intermittent loads of up to 1.5 times the rated load in the specific application. With variable torque load and
constant load without overload, each inverter can also be operated with increased continuous output power (
→
Sec. Technical Data).
The continuous output current of 125% of the rated unit current is only available at f
PWM
= 4 kHz.
[kW]
MCF/MCV/MCH
4_A...-5_3
[kW]
MCF/MCV/MCH
4_A...-5_3
DT71D4
0.37
0.25
0015
0.37
0015
0.55
0015
DT80K4
0.55
0.37
0.55
0.75
DT80N4
0.75
0.55
0.75
1.1
DT90S4
1.1
0.75
1.1
1.5
DT90L4
1.5
1.1
1.5
2.2
0022
DV100M4
2.2
1.5
2.2
0022
3.0
0030
DV100L4
3.0
2.2
0022
3.0
0030
4.0
0040
DV112M4
4.0
3.0
0030
4.0
0040
5.5
0055
DV132S4
5.5
4.0
0040
5.5
0055
7.5
0075
DV132M4
7.5
5.5
0055
7.5
0075
9.2
0110
DV132ML4
9.2
7.5
0075
9.2
0110
11
DV160M4
11
9.2
0110
11
15
0150
DV160L4
15
11
15
0150
18.5
0220
DV180M4
18.5
15
0150
18.5
0220
22
0300
DV180L4
22
18.5
0220
22
30
0370
DV200L4
30
22
30
0300
37
DV225S4
37
30
0300
37
0370
45
0450
DV225M4
45
37
0370
45
0450
55
0550
DV250M4
55
45
0450
55
0550
75
0750
DV280S4
75
55
0550
75
0750
-
DV280M4
90
75
0750
-
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...
Page 432: ......