Explanation of the parameters
Parameters
•
OFF: MOVIDRIVE
®
automatically reduces the set output frequency (down to mini-
mum 4 kHz) when there is a high level of thermal load on the output stage to avoid
a switch-off with the "Unit utilization" error.
P864 PWM
frequency CFC
Setting range: 4 / 8 / 16 kHz
P864 can be used in CFC and SERVO operating modes to set the switching frequency
at the inverter output for parameter set 1. The cycle frequency is set to a fixed value and
is not automatically reduced with high unit utilization.
P87x Process data description
P870 / P871 /
P872 Setpoint
description PO1 /
PO2 / PO3
P870/P871/P872 define the content of the process output data words PO1/PO2/PO3.
This is necessary so MOVIDRIVE
®
can allocate the appropriate setpoints.
The following PO assignments are available:
See "Fieldbus unit profile with parameter list" manual for detailed explanations.
Detailed description of process data.
P873 / P874 /
P875 Actual value
description PI1 /
PI2 / PI3
P873/P874/P875 define the content of the process input data words PI1/PI2/PI3. This is
necessary so MOVIDRIVE
®
can allocate the appropriate actual values.
Setpoint description
Factory setting
P870 Setpoint description PO1
CONTROL WORD 1
P871 Setpoint description PO2
SPEED
P872 Setpoint description PO3
NO FUNCTION
Assignment
Description
NO FUNCTION
The content of the process output data word is ignored
SPEED
Speed setpoint selection in 1/min.
CURRENT [% I
N
]
Current setpoint selection (for torque control)
POSITION LO
Position setpoint low word
POSITION HI
Position setpoint high word
MAX. SPEED
Maximum system speed (P302 / P312).
MAX. CURRENT [% I
N
]
Current limitation in % of I
N
of the inverter (P303 / P313).
SLIP
Slip compensation (P324 / P334).
RAMP
Ramp time for setpoint selection
CONTROL WORD 1
Control signals for start/stop, etc.
CONTROL WORD 2
Control signals for start/stop, etc.
SPEED [%]
Selection of a speed setpoint in % of n
max
IPOS PO-DATA
Specification of a 16-bit coded value for IPOS
plus®
Actual value description
Factory setting
P873 Actual value description PI1
STATUS WORD 1
P874 Actual value description PI2
SPEED
P875 actual value description PI3
NO FUNCTION
P6..
P60.
P600
Summary of Contents for MOVIDRIVE compact MCH41A