Complete parameter list
Startup
83_
Fault responses
830
Response
EXT. FAULT
EMERG. STOP/FAULT
The following fault responses can be programmed: NO
RESPONSE DISPLAY FAULT IMM./FAULT
EMERG.STOP/FAULT RAPID STOP/FAULT IMM.STOP/WARNG
EMERG.STOP/WARNG RAPID STOP/WARNG.
831
Response
FIELDBUS TIMEOUT
RAPID STOP/WARNG
832
Response
MOTOR OVERLOAD
EMERG. STOP/FAULT
833
Response
RS485 TIMEOUT
RAPID STOP/WARNG
834
Response
LAG ERROR
EMERG. STOP/FAULT
835/
Response
TF SIGNAL
NO RESPONSE
836
Response
SBus TIMEOUT
EMERG. STOP/FAULT
84_
Reset behavior
840/ Manual reset
YES / NO
841
Auto reset
ON / OFF
842
Restart time
1...3...30 s
85_
Scaling actual speed value
850
Scaling factor numerator 1...65535
851
Scaling factor
denominator
1...65535
852
User-defined unit
1/min
Can only be set using MOVITOOLS
®
86_
Modulation
860
PWM frequency 1
4/8/12/16 kHz
861 PWM frequency 2
4/8/12/16 kHz
862
PWM fix 1
ON / OFF
863 PWM fix 2
ON / OFF
864
PWM frequency CFC
4/8/16 kHz
87_
Process data description
870
Setpoint description PO1 CONTROL WORD 1
871
Setpoint description PO2 SPEED
872
Setpoint description PO3 NO FUNCTION
873
Actual value description
PI1
STATUS WORD 1
874
Actual value description
PI2
SPEED
875
Actual value description
PI3
OUTPUT CURRENT
876
PO data enable
ON / OFF
877
DeviceNet PD
configuration
0...3...5
88_
Manual operation
880
Manual operation
ON / OFF
Par.
Name
Setting range
Factory setting