116
System Manual – MOVIDRIVE® compact Drive Inverters
3
Explanation of the parameters
Parameters
P11x Analog input AI1
P110 AI1 Scaling
Setting range: –10 ... 0 ... 1 ... 10
The slope of the setpoint characteristic curve is defined. Depending on P112 AI1 Oper-
ating mode with AI1 scaling = 1 and an input voltage V
I
of +/–10 V, the se/–3000
1/min or +/–n
max
is selected.
With P100 Setpoint source = UNIPOL./FIXED SETPT. only the 1st quadrant can be
used, negative setpoint selections then produce the setpoint zero. If a current input is
set in P112 AI1 Operating mode , P110 AI1 scaling will have no effect.
01259BEN
Figure 26: Slope of the setpoint characteristic curve
n
10V
10
2
1
0.5
0.1
-10
-2
-1
-0.5
-0.1
-10V
-5V
5V
V
I
n
3000 rpm
max
n
/2
1500 rpm
max
-n
-3000 rpm
max
-n
/2
-1500 rpm
max
P6..
P60.
P600