System Manual – MOVIDRIVE® compact Drive Inverters
119
3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Explanation of the parameters
Parameters
P114 AI1 speed
offset
Unit: [1/min]
Setting range: –5000 ... 0 ... 5000 1/min
The zero passage of the setpoint characteristic curve can be moved along the n-axis.
P115 Filter setpoint
Unit: [ms]
Setting range: T = 0 ... 5 ... 100 ms (0 = setpoint filter Off)
The speed ramp is filtered. The filter can be used for dampening stepped setpoint se-
lections, e.g. from external controllers or interference pulses at the analog input. Also
applies for torque control.
58610AEN
Figure 30: AI1 speed offset
Reference point
with positive offset
Reference point
with negative offset
-10 V
0 V
2 V
4 V
6 V
8 V
10 V
-8 V
-6 V
-4 V
-2 V
01265BEN
Figure 31: Effect of setpoint filter
T
t
63%
V
e
0
0
T
t
37%
0
0
Setpoint step change
Unit step response
V
Setpoint step change
Unit step response
V
V
e
P6..
P60.
P600