144
System Manual – MOVIDRIVE® compact Drive Inverters
3
Explanation of the parameters
Parameters
P642 Operating
mode AO1
Here you can set the operating mode of the analog output. The following operating
modes are available:
•
OFF: The value zero is always output.
•
0 ... 20 mA: Output of the value of the reference values as current values 0 ... 20 mA
at AO1. P641 Scaling AO1 will be evaluated as an absolute number.
•
4 ... 20 mA: Output of the value of the reference values as current values 4 ... 20 mA
at AO1. The slope of the characteristic curves is flatter than in 0 ... 20 mA. The char-
acteristic curve has an offset of 4 mA and the absolute of P641 Scaling AO1 refers
to the value range of 16 mA.
01306BEN
Figure 45: Characteristic curve of operating mode 0... 20 mA
01307BEN
Figure 46: Characteristic curve of operating mode 4... 20 mA
20 mA
10
2
1
0.5
0.1
10
2
1
0.5
0.1
10 mA
4 mA
Reference
value
Output value
-3000 rpm
-100 Hz
-150%
-10 000 Dig.
+3000 rpm
+100 Hz
+150%
+10 000 Dig.
IPOS OUTPUT
UNIT UTILIZATION, CURRENT, RELATIVE TORQUE
ACTUAL FREQUENCY
RAMP INPUT, SPEED
20 mA
10
2
1
0.5
0.1
10
2
1
0.5
0.1
10 mA
4 mA
Reference
value
Output value
-3000 rpm
-100 Hz
-150%
-10 000 Dig.
+3000 rpm
+100 Hz
+150%
+10 000 Dig.
IPOS OUTPUT
UNIT UTILIZATION, CURRENT, RELATIVE TORQUE
ACTUAL FREQUENCY
RAMP INPUT, SPEED
P6..
P60.
P600
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...
Page 432: ......