320
System Manual – MOVIDRIVE® compact Drive Inverters
9
Connection of motor encoder and external encoder
Installation
Resolver (only for
MCS4_A)
Depending on the motor type and motor configuration, you can connect the resolver
using either a plug connector or via the terminal box.
DS56, CM71...112
with plug connec-
tor
The resolver connections are accommodated in a plug connector.
Plug connector DS56, CM:
Intercontec, type ASTA021NN00 10 000 5 000
Part numbers of the prefabricated cables:
•
For fixed installation:
199 487 5
•
For cable carrier installation:
199 319 4
Part numbers of the prefabricated extension cables:
•
For fixed installation:
199 542 1
•
For cable carrier installation:
199 541 3
DS56, CM71...112
with terminal box
The resolver connections are accommodated in the terminal box on a 10-pin Phoenix
terminal strip.
Cut off the violet conductor (VT) of the cable at the encoder end.
Part numbers of the prefabricated cables:
•
For fixed installation:
199 589 8
•
For cable carrier installation:
199 590 1
59857AXX
Figure 127: Resolver connection for DS56 and CM motors with plug connector
max. 100 m
59858AXX
Figure 128: Resolver connection for DS and CM motors with terminal box
max. 100 m