System Manual – MOVIDRIVE® compact Drive Inverters
299
9
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Wiring diagram for basic unit
Installation
Analog output
AO1
For MCF40A/MCV/MCS40A, the binary output DOØ2 (X10:19) can also be used as
0(4)...20 mA analog output AO1. Switch the settings with parameters P621 "Binary out-
put DOØ2" and P642 "Operating mode AO1."
MCV41A: Assigning electronics terminals and the label
NOTE
Note the following for MCS4_A: If a TH/TH is connected to X15:5 and X15:9, then no
TF/TH connection is permitted at X10:1 and X10:6. Do not use terminal X10:6 in this
case, not even as a DC 10 V voltage input. In MOVITOOLS
®
, set P120 to "TF" and set
the corresponding error response with P835.
Function of X10:19
P621 "Binary output DOØ2"
P642 "Operating mode AO1"
Binary output DOØ2
≠
set NO FUNCTION
= set OFF
Analog output AO1
= set NO FUNCTION
≠
set OFF
≠
set NO FUNCTION
≠
set OFF
No function
= set NO FUNCTION
= set OFF
59896AXX
Figure 114: Electronics terminals and label on MCV41A
1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
X 10
R EF 1
R EF 2
S C11
S C12
DIØØ
DIØ2
DIØ4
DCOM
DGND
DOØ2
DBØØ
DGND
AI11
AI12
AI21
AGND
DIØ1
DIØ3
DIØ5
V O24
DOØ1-C
DOØ1-NO
DOØ1-NC
V I24
MCV41A
1
5
6
9
5
1
9
6
X15
ENCODER IN
X15
ENCODER I/O
1
5
6
9
PROFIBUS DP
X30
RUN
BUS
FAULT
max 24V !
(EN 61131-2)
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...
Page 432: ......