System Manual – MOVIDRIVE® compact Drive Inverters
345
10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Complete parameter list
Startup
5__
MONITORING FUNCTIONS
50_
Speed monitoring
500
Speed monitoring 1
OFF / MOTOR
/REGENERATIVE
/MOT®EN.MODE
502 Speed monitoring 2
OFF / MOTOR
/REGENERATIVE
/MOT®EN.MODE
501
Deceleration time 1
0...1...10 s
503 Deceleration time 2
0...1...10 s
504
Encoder monitoring
ON / OFF
52_
Mains OFF monitoring
520
Mains OFF response
time
0...5 s
521
Mains OFF response
CONTROL.INHIBIT
EMERGENCY STOP
53_
Motor temperature protection
530
Sensor type 1
No sensor / TF-TH
531
Sensor type 2
No sensor / TF-TH
6__
TERMINAL ASSIGNMENT
60_
Binary inputs basic unit
-
Binary input DIØØ
With fixed assignment with: /CON-
TROLLER INHIBIT
600
Binary input DIØ1
CW/STOP
The following functions can be programmed: NO FUNCTION
•
ENABLE/RAP.STOP
•
CW/STOP
•
CCW/STOP
•
n11(n13)
•
n21(n23)
•
n12(n13)
•
n22(n23)
•
FIX SETPT SW.OV.
•
PAR.
SWITCHOVER
•
RAMP SWITCHOVER
•
MOTOR POT UP
•
MOTOR POT DOWN
•
/EXT. FAULT
•
FAULT RESET
•
/HOLD
CONTROL
•
/LIM. SWITCH CW
•
/LIM. SWITCH CCW
•
IPOS
INPUT
•
REFERENCE CAM
•
REF.TRAVEL START
•
SLAVE
FREE RUNN.
•
SETPOINT HOLD
•
MAINS ON
•
DRS SET
ZERO.
601
Binary input DIØ2
CCW/STOP
602
Binary input DIØ3
ENABLE/STOP
603
Binary input DIØ4
n11/n21
604
Binary input DIØ5
n12/n22
62_
Binary outputs basic unit
The following signals can be programmed: NO FUNCTION
•
/FAULT
•
READY
•
OUTP. STAGE ON
•
ROT. FIELD ON
•
BRAKE RELEASED
•
BRAKE APPLIED
•
MOTOR STANDSTILL
•
PARAMETER SET
•
SPEED REFERENCE
•
SPEED WINDOW
•
SP/ACT.VAL.COMP.
•
CURR. REFERENCE
•
Imax- SIGNAL
•
/MOTOR UTILIZ. 1
•
/MOTOR UTILIZ. 2
•
IPOS IN POSITION
•
IPOS REFERENCE
•
IPOS OUTPUT
•
/IPOS FAULT
-
Binary output DBØØ
With fixed assignment with: /BRAKE
620
Binary output DOØ1
READY FOR OPERA-
TION
621
Binary output DOØ2
NO FUNCTION
64_
Analog output
640
Analog output AO1
ACTUAL SPEED
The following functions can be programmed: NO FUNCTION
•
RAMP INPUT
•
SPEED SETPOINT
•
ACTUAL SPEED
•
ACTUAL FREQUENCY
•
OUTPUT CURRENT
•
ACTIVE CUR-
RENT
•
UNIT UTZILIZATION
•
IPOS OUTPUT
•
RELATIVE
TORQUE
641
Scaling AO1
-10...0...1...10
642
Operating mode AO1
OFF / 0...20 mA / 4...20
mA
7__
CONTROL FUNCTIONS
70_
Operating modes
700
Operating mode 1
VFC 1
VFC 1 & GROUP
VFC 1 & HOIST
VFC 1 & DC BRAK.
VFC 1 & FLYSTART
VFC n-CONTROL
VFC-n-CTRL&GRP.
VFC-n-CTRL&HOIST
VFC-n-CTRL& IPOS
CFC
CFC & M-CONTROL
CFC&IPOS
SERVO
SERVO&M-CONTROL
SERVO&IPOS
701 Operating mode 2
VFC 2
VFC 2 & GROUP
VFC 2 & HOIST
VFC 2 & DC BRAK.
VFC 2 & FLYSTART
71_
Standstill current
710
Standstill current 1
0...50 % I
mot
711 Standstill current 2
0...50 % I
mot
Par.
Name
Setting range
Factory setting
after
start-up
Par. Name
Setting range
Factory setting
after
start-up
Selectable par.
Parameter set 1
Parameter set 2
0
0
I