System Manual – MOVIDRIVE® compact Drive Inverters
343
10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Complete parameter list
Startup
Par.
Name
Setting range
Factory setting
after
start-up
Par. Name
Setting range
Factory setting
after
start-up
Selectable par.
Parameter set 1
Parameter set 2
1__
SETPOINTS / RAMP GENERATORS
10_
Setpoint selection
100/ Setpoint source
UNIPOL/FIX.SETPT
101
Control signal source
TERMINALS
11_
Analog input AI1
110
AI1 scaling
–10...-0.1 / 0.1...1...10
111
AI1 Offset
–500...0...500 mV
112
AI1 operating mode
Ref. N-MAX
113
AI1 voltage offset
–10...0...10 V
114
AI1 speed offset
–5000...0...5000 1/min
115
Filter speed setpoint
0...5...100 ms 0 = Filter
off
12_
Analog input AI2
120
AI2 operating mode
NO FUNCTION
13_
Speed ramps 1
14_ Speed ramps 2
130/ Ramp t11 up CW
0...2...2000 s
140 Ramp t21 up CW
0...2...2000 s
131/ Ramp t11 down CW
0...2...2000 s
141 Ramp t21 down CW
0...2...2000 s
132/ Ramp t11 up CCW
0...2...2000 s
142 Ramp t21 up CCW
0...2...2000 s
133/ Ramp t11 down CCW
0...2...2000 s
143 Ramp t21 up CCW
0...2...2000 s
134/ Ramp t12 UP=DOWN
0...2...2000 s
144 Ramp t22 UP=DOWN 0...2...2000 s
135
S pattern t12
0...3
145 S pattern t22
0...3
136/ Stop ramp t13
0...2...20 s
146 Stop ramp t23
0...2...20 s
137/
Emergency stop ramp
t14
0...2...20 s
147
Emergency stop ramp
t24
0...2...20 s
15_
Motor potentiometer (parameter sets 1 and 2)
150
Ramp t3 up
0.2...20...50 s
151
Ramp t3 down
0.2...20...50 s
152
Save last setpoint
ON / OFF
16_
Fixed setpoints 1
17_ Fixed setpoints 2
160/ Internal setpoint n11
–5000...0...150 ...5000
1/min
170 Internal setpoint n21
–5000...0...150 ...5000
1/min
161/ Internal setpoint n12
–5000...0...750 ...5000
1/min
171 Internal setpoint n22
–5000...0...750 ...5000
1/min
162/ Internal setpoint n13
–5000...0...1500 ...5000
1/min
172 Internal setpoint n23
–5000...0...1500 ...5000
1/min
2__
CONTROLLER PARAMETERS
20_
Speed control (only parameter set 1)
200
P-gain
n-controller
0.1...2...32
201
Time constant n-control-
ler
0...10...300 ms
202
Gain
Accel. feedforw.
0...32
203
Filter accel. feedforw.
0...100 ms
204
Filter speed actual value 0...32 ms
205
Load feedforward
0...150 %
206
Sampling time n-control-
ler
1 ms / 0.5 ms
207
Load feedforw. VFC
0...150 %
21_
Hold controller
210
P gain hold controller
0.1...2...32
22_
Internal synchronous operation (only parameter set 1)
228
Feedforward filter (DRS) 0...100 ms
Only with MOVITOOLS
®
. Not visible on the DBG11B keypad.
0
0
I
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...
Page 432: ......