Explanation of the parameters
Parameters
Torque control
Torque control of the slave (TORQUE (SBus)):
The slave inverter receives the torque setpoint of the master directly (the correcting vari-
able of the speed controller). This also enables high quality load distribution to be
achieved, for example. This setting should be preferred over load sharing if the drive
configuration permits it. Set the speed ratio with P751 Scaling slave setpoint.
Example:
P750 Slave
setpoint
The setpoint to be transferred to the slave is set on the master. The "MASTER-SLAVE
OFF" setting must be retained on the slave.
•
MASTER-SLAVE OFF
•
SPEED (SBus)
•
TORQUE (SBus)
•
LOAD SHARE (SBus)
P751 Scaling slave
setpoint
Setting range: –10 ... 0 ... 1 ... 10
When this setting is made in the slave, the setpoint transferred from the master is
multiplied by this factor.
Parameters
Setting on the master
Setting on the slave
e.g. UNIPOL./FIXED SETP
MASTER SBus
e.g. TERMINALS
Not in effect
CFC
CFC & M-CONTROL
TORQUE (SBus)
MASTER-SLAVE OFF
Not in effect
1 (then 1 : 1)
Set different values
P814 SBus groupaddress
Set the same value (0 ... 63)
P816 SBus baud rate
Set the same value (125, 250, 500 or 1000 kBaud)
P6..
P60.
P600