Explanation of the parameters
Parameters
P720 / P723 Set-
point stop function
1/2
Setting range: ON / OFF
P721 / P724 Stop
setpoint 1 / 2
Setting range: 0 ... 30 ... 500 1/min
In the VFC&Hoist operating mode, the minimum stop setpoint is internally limited to
16 1/min.
P722 / P725 Start
offset 1/2
Setting range: 0 ... 30 ... 500 1/min
There is no enable for stop se start offset (start setpoint) > n
max
.
Movement with n
min
is never possible if the stop setpoint is > n
min
.
P73x Brake
function
MOVIDRIVE
®
inverters are capable of controlling a brake installed on the motor. The
brake function acts on the binary output DBØØ which has the fixed assignment of the
'/BRAKE' function (24 V = brake released). In drives with encoder feedback (speed con-
trol), it is possible to select between electrical holding of the load and mechanical appli-
cation of the brake in halt condition.
P730 / P733 Brake
function 1/2
Setting range: ON / OFF
This function determines whether the brake is to be activated when the enable is with-
drawn (enable = "0"). The brake is always active in controlled hoist operation.
1
2
1
2
1
2
NOTE
The brake is always applied when /CONTROL.INHIBIT = 0.
55734BEN
Figure 48: Inverter behavior with activated brake function
t
0
t
t
t
t
t
t
"1"
"1"
"1"
"1"
"0"
"0"
"0"
"0"
Rotating field ON
Brake
release time
Brake
application time
Output stage ON
Pre-magnetization time
/BRAKE
Enable
nset
nstart/stop
n
Post-magnetization time
1
2
P6..
P60.
P600