Explanation of the parameters
Parameters
P62x Binary out-
put basic unit
Use binary output DBØØ for controlling the brake. This binary output has the fixed as-
signment of the “/BRAKE” function. The “BRAKE RELEASED” and “BRAKE APPLIED”
signals are intended to be passed on to a master controller.
Important: The binary signals are only valid if the inverter has signaled “Ready” after
switch-on and there is no error display. Binary signals have “0“ status while
MOVIDRIVE
®
is being initialized. Several terminals can be assigned the same function.
P620 ... P624
Binary output
DOØ1 ... DOØ5
The binary outputs of the basic unit can be set to the same functions as the binary out-
puts option (P63x).
P6..
P60.
P600