222
System Manual – MOVIDRIVE® compact Drive Inverters
4
Overload capacity of the inverter
Project Planning
Cycle frequency f
PWM
= 16 kHz:
56714AXX
Figure 67: Overload capacity at f
PWM
= 16 kHz (400 V / 40 °C)
t [T]
1
t [T]
2
1
26
%
I
D
60 % I
D
40 % I
D
20 % I
D
0 % I
D
V = 3 x AC 400 V
1
amb
PWM
=
f
(P860 / P861) =
40 °C
16 kHz
I
out 2
I
out 1
ϑ
2
1.5
1
0.5
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5