System Manual – MOVIDRIVE® compact Drive Inverters
339
10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Starting the motor
Startup
Fixed setpoints
The following table shows which signals must be present on terminals DIØØ ... DIØ5
when the "UNIPOL/FIX.SETPT" setpoint is selected (P100), to operate the drive with the
fixed setpoints.
Travel diagram
The following travel diagram is an example of how the drive is started with the wiring of
terminals DIØØ DIØ5 and the internal fixed setpoints. Binary output DBØØ "/Brake" is
used for switching brake contactor K12.
Function
DIØØ
/Controller
inhibit
DIØ1
CW/Stop
DIØ2
CCW/Stop
DIØ3
Enable/Stop
DIØ4
n11/n21
DIØ5
n12/n22
Controller inhibit
"0"
X
X
X
X
X
Stop
"1"
X
X
"0"
X
X
Enable and stop
"1"
"0"
"0"
"1"
X
X
CW operation with n11
"1"
"1"
"0"
"1"
"1"
"0"
CW operation with n12
"1"
"1"
"0"
"1"
"0"
"1"
CW operation with n13
"1"
"1"
"0"
"1"
"1"
"1"
CCW operation with n11
"1"
"0"
"1"
"1"
"1"
"0"
05034BEN
NOTE
The motor is not energized in the event of controller inhibit (DIØØ = "0"). A motor
without brake will coast to standstill.
"1"
"1"
"1"
"1"
"1"
"1"
"0"
"0"
"0"
"0"
"0"
"0"
n13
n12
-n12
-n13
0
"1"
"0"
n11
-n11
n [min
]
-1
Input DIØØ
/Controller inhibit
Input DIØ1
CW/stop
Input DIØ2
CCW/stop
Input DIØ3
Enable/stop
Input DIØ4
n11/n21
Input DIØ5
n12/n22
Speed
Output DBØØ
/Brake
t11 up CW
t11 up CW
t11 up CW
t11 down CW
t11 up CCW
Stop ramp t13
0
0
I