Connection of motor encoder and external encoder
Installation
On the
encoder/resolver
Connect the shield on the encoder/resolver side at the respective grounding clamps (
→
following illustration). When using an EMC screw fitting, apply the shield over a wide
area in the cable gland. For drives with a plug connector, connect the shield on the en-
coder plug.
Prefabricated
cables
SEW-EURODRIVE offers prefabricated cables for connecting encoders/resolvers. We
recommend using these prefabricated cables.
Motor encoder
You can connect the following motor encoders at X15 on the MOVIDRIVE
®
compact
units:
•
MCV4_A
– High-resolution sin/cos encoders with signal voltage AC 1 V
SS
– TTL sensors with signal level to RS422
– HTL sensors
•
MCS4_A
– 2-pole resolvers, AC 7 V
eff
/ 7 kHz
•
MCH4_A
– Hiperface encoder
– High-resolution sin/cos encoders with signal voltage AC 1 V
SS
– TTL sensors with signal level to RS422
55513AXX
1
2
3 4 5
6
7 8
9 10
1
2
3 4 5
6
7 8
9 10
05232AXX
Figure 119: SEW encoder with plug connector or connecting terminal