398
System Manual – MOVIDRIVE® compact Drive Inverters
11
DBG11B keypad
Operation
Selected via menu
02407AEN
Figure 164: Menu structure
01406AXX
←
or
→
key
Change the menu level, in the 3rd menu level (parameter), enter (
→
) or leave (
←
)
the edit mode. The parameter can only be changed in edit mode. Pressing the
←
and
→
keys at the same time, triggers startup (
→
Sec. "Startup").
↑
or
↓
key
Select the menu item; in edit mode, select higher or lower value. The new value
takes effect when you release the
↑
or
↓
key in edit mode.
Q key
Back to the basic display; in startup mode, startup is terminated.
E key
Startup:
Termination of startup
Normal operation:
Signature is displayed; the signature can only be entered or
changed using MOVITOOLS/SHELL. It is used to identify the
parameter set or the unit.
Manual mode:
Leave manual mode
In case of
malfunction:
Reset parameter P840 is called up
[ ]
↑
[ ]
↑
[ ]
↑
[ ]
↓
[ ]
↓
[ ]
↓
[
]
←
[
]
←
[
]
←
[
]
→
[
]
→
[
]
→
1st Menu level
Main menu
2nd Menu level
Submenu
3rd Menu level
Parameters
Editing mode
11
1
A11
SCALING
0
11
REF. NMAX
A11 OPERAT. MODE
2
11
0 V
A11
V-OFFSET
3
11
0 /M
A11
n-OFFSET
4
11
1.89 ms
SETPOINT FILTER
5
11
0 mV
A11
OFFSET
1
111
mV
A11
OFFSET
0
0.. DISPLAY
VALUES
CONTR. INHIBIT
CURR.:
0 A
1 . SETPOINT
SELECTION
0
1.. SETPOINTS/
RAMP GENERATORS
1 . ANALOG INP. 1
(+/- 10 V)
1
1 . ANALOG
INPUT AI2
2
3.. MOTOR
PARAMETERS
1 . SPEED
RAMPS 1
3
4.. REFERENCE
SIGNALS
1 . SPEED
RAMPS 2
4
5.. MONITORING
FUNCTIONS
1 . MOTOR. POT.
5
6.. TERMINAL
ASSIGNMENT
1 . FIXED
SETPOINTS 1
6
7.. CONTROL
FUNCTIONS
1 . FIXED
SETPOINTS 2
7
8.. UNIT
FUNCTIONS
9.. IPOS
PARAMETERS
E
Q