400
System Manual – MOVIDRIVE® compact Drive Inverters
11
DBG11B keypad
Operation
Information
messages
Information messages on the DBG11B (ca. 2 s long) or in MOVITOOLS/SHELL
(message that can be acknowledged):
No.
Text in
DBG11B/SHELL
Description
1
ILLEGAL INDEX
Index addressed via interface not available.
2
NOT IMPLEMENT.
•
Attempt to execute a function that is not implemented.
•
An incorrect communication service has been selected.
•
Manual operation selected via invalid interface (e.g. fieldbus).
3
READ ONLY VALUE
You tried to change a read only value.
4
PARAM. LOCKED
Parameter lock P803 = "ON", Parameter cannot be altered.
5
SETUP ACTIVE
You tried to change parameters when factory setting is active.
6
VALUE TOO HIGH
You tried to enter a value that is too high.
7
VALUE TOO LOW
You tried to enter a value that is too low.
8
REQ. CARD MISSING
The option card required for the selected function is missing.
--
--
11
ONLY TERMINAL
Manual mode must be exited via TERMINAL (DBG11B or USS21A).
12
NO ACCESS
Access to selected parameter denied.
13
CTRL. INHIBIT
MISSING
Set terminal DIØØ "/Controller inhibit" = "0" for the selected function.
14
INVALID VALUE
You tried to enter an invalid value.
--
16
PARAM. NOT LOCKED
Overflow of EEPROM buffer, e.g. through cyclic write access. Parameter
not stored in non-volatile EEPROM.
17
INVERTER ENABLED
•
Parameter to be changed can only be set in the state "CONTROLLER
INHIBIT."
•
You tried to change to manual mode during live operation.