294
System Manual – MOVIDRIVE® compact Drive Inverters
9
Touch guard
Installation
9.6
Touch guard
When the touch guard is installed, MOVIDRIVE
®
compact
sizes 4 and 5 provide enclo-
sure protection IP10; without touch guard IP00.
Two touch guards with 8 retaining screws are supplied as standard with MOVIDRIVE
®
compact
sizes 4 and 5. Install the touch guard on both covers of the power section ter-
minals.
DANGER!
Uncovered power connections.
Severe or fatal injuries from electric shock.
•
Install the touch guard according to the regulations.
•
Never start the unit if the touch guard is not installed.
06624AXX
Figure 112: Touch guard for MOVIDRIVE
®
compact sizes 4 and 5
[1]
Cover
[2]
Connection plate
[3]
Aperture
[1]
[2]
[3]