General information
Safety Notes
7
Safety Notes
The following basic safety notes must be read carefully to prevent injury to persons and
damage to property. The operator must make sure that the basic safety notes are read
and observed. Make sure that persons responsible for the plant and its operation, as
well as persons who work independently on the unit, have read through the operating
instructions carefully and understood them. If you are unclear about any of the
information in this documentation, or if you require further information, please contact
SEW-EURODRIVE.
7.1
General information
Never install damaged products or take them into operation. Submit a complaint to the
shipping company immediately in the event of damage.
During operation, drive inverters can have live, bare and movable or rotating parts as
well as hot surfaces, depending on their enclosure.
Removing covers without authorization, improper use or incorrect installation and
operation may result in severe injuries to persons or damage to machinery.
Consult the documentation for additional information.
7.2
Target group
Only qualified personnel are authorized to install, start up, repair or service the units
(observe IEC 60364 or CENELEC HD 384 or DIN VDE 0100 and IEC 60664 or DIN
VDE 0110 as well as national accident prevention guidelines).
Qualified personnel in the context of these basic safety notes are: all persons familiar
with installation, assembly, startup and operation of the product who possess the
necessary qualifications.
All persons involved in any other work, such as transportation, storage, operation and
disposal, must have suitable training.
7.3
Designated use
Drive inverters are components intended for installation in electrical systems or
machines.
In case of installation in machines, startup of the drive inverters (i.e. start of designated
operation) is prohibited until it is determined that the machine meets the requirements
stipulated in the EC Directive 98/37/ EC (machine guideline); observe EN 60204.
Startup (i.e. start of designated operation) is only permitted with adherence to
EMC (89/336/EEC) guideline.
The drive inverters meet the requirements stipulated in low voltage guideline
73/23/EEC. The harmonized standards of the EN 61800-5-1/DIN VDE T105 series in
connection with EN 60439-1/VDE 0660 part 500 and EN 60146/VDE 0558 are applied
to these drive inverters.
Technical data and information on the connection requirements are given on the
nameplate and in the documentation; they have to be observed under all circumstances.
Safety functions
The MOVIDRIVE
®
compact
drive inverters may not perform safety functions without
higher-level safety systems. Use higher-level safety systems to ensure protection of
personnel and equipment.