System Manual – MOVIDRIVE® compact Drive Inverters
121
3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Explanation of the parameters
Parameters
The expert characteristic curves displayed in Figure 32 are created as follows:
The expert characteristic curve can also be used with P100 Setpoint source =
UNIPOL./FIX.SETPT.. The direction of rotation is specified using binary inputs. The ex-
pert characteristic curve is reflected on the x-axis. The section below the x-axis results
in a speed setpoint = 0. In case of set direction of rotation "CW", only speeds in the range
0 ... n
max
will be executed; for set direction of rotation "CCW" only speeds in the range
0 ... –n
max
will be executed. Figure 33 shows the expert characteristic curves from
Figure 33 at the setting P100 Setpoint source = UNIPOL/FIX.SETPT.
Characteristic
curve
1
0
0
1
2
4
500
1.39
3
0
1500
1
4
0
3000
–1.25
02143CEN
Figure 33: Samples of expert characteristic curves with P100 Setpoint source = UNI-
POL./FIX.SETPT.
P6..
P60.
P600
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...