System Manual – MOVIDRIVE® compact Drive Inverters
397
11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
DBG11B keypad
Operation
11.4
DBG11B keypad
Basic displays
DBG11B copy
function
You can use the DBG11B keypad to copy parameter sets from one MOVIDRIVE
®
unit
to other MOVIDRIVE
®
units. To do so, copy the parameter set to the keypad with P 807
(MD_
→
DBG). Plug the keypad into another MOVIDRIVE
®
unit and copy the parameter
set with P 806 (DBG
→
MD_). You can plug in or remove the keypad during operation.
No connection
between inverter
and DBG11B
If a connection cannot be established with the keypad once the mains power has been
switched on or the DC 24 V supply connected, one of the following fault messages can
appear:
Try to establish the connection by removing the keypad and plugging it in again. If you
cannot establish a connection, send the unit (DBG11B keypad, maybe also
MOVIDRIVE
®
) to SEW-EURODRIVE for repair or replacement.
CONTROLLER INHIBIT
CURRENT:
0
A
Display when X11:1 (DIØØ "/CONTROLLER INHIBIT") = "0".
NO ENABLE
CURRENT:
0
A
Display for X11:1 (DIØØ "/CONTROLLER INHBIT") = "1" and
disabled inverter ("ENABLE/STOP" = "0").
SPEED 942 1/min
CURRENT:
2.51 A
Display for enabled inverter.
NOTE XX
XXXXXXXXXXXXXXXXXXX
Information message
FAULT XX
XXXXXXXXXXXXXXXXXXX
Fault display
COMMUNIC. ERROR
NO SERIAL LINK
There may also be a fault in the MOVIDRIVE
®
unit
ERROR WHILE COPY
FLASH ERR. XX
Error in the DBG11B keypad
FATAL ERROR!
CODE CRC WRONG
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...