Explanation of the parameters
Parameters
P4xx Reference signals
The following reference values are used for recording and signaling certain operating
states. All signals from parameter group P4xx can be issued via binary outputs (P62x
Binary outputs basic unit / P63x Binary outputs option).
Important:The signals are only valid if the inverter has signaled “Ready” after switch-on
and there is no error display.
P40x Speed
reference signal
Signal if the speed is less than or greater than the set reference speed.
P400 Speed
reference value
Setting range: 0 ... 1500 ... 5000 1/min
P401 Hysteresis
Setting range: 0 ... 100 ... 500 1/min
P402 Delay time
Setting range: 0 ... 1 ... 9 s
P403 Signal = “1“
when:
n < n
ref
/ n > n
ref
01619BEN
Figure 40: Speed reference signal
n
ref
-n
ref
P401
P400
t
P402
1
1
0
0
t
t
n [rpm]
P403: Signal = "1" at |n| < n
ref
P403: Signal = "1" at |n| > n
ref
P6..
P60.
P600