System Manual – MOVIDRIVE® compact Drive Inverters
3
Explanation of the parameters
Parameters
P09x Bus diagnostics
P090 PD configu-
ration
Set process data configuration.
P091 Fieldbus type
Installed fieldbus type:
•
PROFIBUS DP
•
INTERBUS
•
NO FIELDBUS
P092 Baud rate
fieldbus
Active baud rate.
P093 Fieldbus
address
Address of the inverter on the fieldbus.
P094 ... P096 PO1
... PO3 setpoint
Displays the value currently transferred on the process data word in hexadecimal form.
P097 ... P099 PE1
... PI3 actual value
Displays the value currently transferred on the process data word in hexadecimal form.
P1xx Setpoints / ramp generators
P10x Setpoint selection
P100 and P101 can also be used for selecting a communication port as the setpoint or
control signal source. However, the interfaces are not automatically deactivated with
these parameters because the drive inverter must remain ready to receive via all inter-
faces at any time.
Fixed setpoints have priority over other setpoints.
If the drive inverter is in "t = Wait for data" status, please check the timeout intervals of
parameters P812, P815 and P819 and, if necessary, switch off timeout monitoring by
entering 0 s or 650 s.
P100 Setpoint
source
This parameter is used to set the setpoint source for the inverter.
•
BIPOL./FIX.SETPT: The setpoint is provided by the analog inputs (AI1/AI2) or P16x
Fixed setpoints 1, if these are selected via P60x Binary inputs basic unit / P61x Bi-
nary inputs option . The setpoints are processed according to their signs. Positive
setpoint results in CW rotation, negative setpoint in CCW rotation.
•
UNIPOL./FIX.SETPT: The setpoint is provided by the analog inputs or the fixed set-
points. Negative analog setpoints result in a setpoint of zero. The fixed setpoints are
processed in accordance with their value. The direction of rotation is specified via
P60x Binary inputs basic unit / P61x Binary inputs option.
•
RS485: The setpoint comes from the RS485 interface.
•
FIELDBUS: The setpoint comes from the fieldbus interface.
PO setpoint
Description
P094 PO1 setpoint
P095 PO2 setpoint
P096 PO3 setpoint
PI setpoint
Description
P097 PI1 actual value
P873 Actual value description PI1
P098 PI2 actual value
P874 Actual value description PI2
P099 PI3 actual value
P875 Actual value description PI3
P6..
P60.
P600