86
System Manual – MOVIDRIVE® compact Drive Inverters
2
Output filter HF...
Technical Data and Dimension Drawings
Dimension drawings for output filter HF...-503, all dimensions in mm
HF008/015/022/030-503
HF040/055/075-503
58418AXX
Figure 22: Dimension drawings for output filters HF008...075-503
Only the mounting position shown in the dimension drawing is permitted.
Output filter type
Main dimensions
Mounting dimensions
Hole dimension
Ventilation
clearances
1)
1) There is no need for clearance at the sides. You can line up the units next to one another.
A
B
C
a
b
c
Above
Below
HF008/015/022/030-503
80
286
176
-
265
7
100
100
HF040/055/075-503
135
296
216
70
283
HF450-503
58417AXX
Figure 23: Dimension drawing for output filter HF450-503
Only the mounting position shown in the dimension diagram is permitted
Output filter type
Main dimensions
Mounting dimensions
Hole dimension
Ventilation clearances
A
B
C
a
b
c
Above
Below
HF450-503
465
385
240
436
220
8.5
100
100
b
b
c
a
c
C
C
A
A
B
B
MOVIDRIVE®
MOVIDRIVE®
W1
W2
V1
V2
V5
U1
4
5
6
8
U2
MOVIDRIVE®
M
~
1
1
1
a
b
B
c
A
C
4 5 6 7 U V W
P
i
f
kVA
Hz
n
Summary of Contents for MOVIDRIVE compact MCH41A