11
Operating displays for MC_40A (without fieldbus)
Operation
11
Operation
11.1
Operating displays for MC_40A (without fieldbus)
The operating status of MOVIDRIVE
®
compact
MC_40A are displayed on LED V1.
[1] Operation LED V1 (three colors: green/red/yellow)
Operation LED V1
The operating status of MOVIDRIVE
®
compact
MC_40A is displayed by the three-color
LED V1 (green/red/yellow).
05428BXX
Figure 160: MOVIDRIVE
®
compact MC_40A operating display
[1]
Color
Operating state
Description
-
OFF
Without voltage
No supply voltage and no DC 24 V
backup voltage.
Yellow
Steady light
Controller inhibit or
No enable
Unit ready but controller inhibit active
(DIØØ = "0") or no enable.
Green
Steady light
Enable
Motor is energized.
Red
Steady light
Locking system error
Error causes unit to disconnect.
Yellow
Flashing
Unit not ready
Factory setting in progress or DC 24 V
backup mode without supply voltage.
Green
Flashing
Flying start in process
Operating mode VFC & FLYING
START is set and inverter connected
to a rotating motor.
Green/red
Flashing
0.5 s green / 0.5 s red
Limit switch contacted
Limit switch reached in "enable"
operating status.
Yellow/red
Flashing
0.5 s yellow / 0.5 s red
Limit switch contacted
Limit switch reached in "Controller
inhibit" operating status.
Green/red
Flashing
green green red red
Display or wait system
error
Fault in "enable" operating status.
Fault is only displayed and does not
lead to a switch-off.
Yellow/red
Flashing
yellow yellow red red
Display or wait system
error
Fault in "controller inhibit" operating
status. Fault is only displayed and
does not lead to a switch-off.
Green/yellow
0.75 s green /
0.75 s yellow
Timeout active
Enable ineffective, inverter is waiting
for a valid telegram.