P35x Motor sense
of rotation
SEW-EURODRIVE specifies the direction of rotation as seen onto the drive side of the
motor. Clockwise (positive) is defined as rotation to the right and counterclockwise as
rotation to the left. This definition is implemented when the motor is connected according
to the SEW designation.
P350 / P351
Change direction
of rotation 1/2
Setting range: ON / OFF
•
ON: Above definition is reversed. The assignment of limit switches is maintained.
When the motor turns in CLOCKWISE direction, the drive will be properly stopped
once it hits the right limit switch. It is important to carefully check that the limit switch
is connected properly and the reference point and travel positions are defined cor-
rectly when using this parameter.
•
OFF: The SEW definition applies.
P36x Startup
Startup (only available in the DBG11B keypad).
P360 Startup
Setting range: YES / NO
•
YES: Begins the startup function with the DBG11B keypad.
•
NO: The startup function is not begun.
Change in direction of rotation
Positive setpoint
(positive direction of travel)
Negative setpoint
(negative direction of travel)
OFF
Motor turns clockwise
Motor turns counterclockwise
ON
Motor turns counterclockwise
Motor turns clockwise
NOTE
Altering the 'Change direction of rotation' parameter after the system has been moved
to its reference point causes the system to lose its reference point for the absolute
position. The result may be undesirable travel movements of the axis.
NOTE
With P360, MOVIDRIVE
®
can only be started up in VFC operating modes. Startup in
CFC and SERVO operating modes requires MOVITOOLS/SHELL.
P6..
P60.
P600