108
System Manual – MOVIDRIVE® compact Drive Inverters
3
Overview of parameters
Parameters
IPOS Monitoring
CW SW limit switch
–(2
31
–1) ... 0 ... 2
31
–1 inc.
CCW SW limit switch
–(2
31
–1) ... 0 ... 2
31
–1 inc.
Position window
0 ... 50 ... 32 767 inc.
Lag error window
0 ... 5000 ... 2
31
–1 inc.
IPOS Special functions
Override
ON / OFF
IPOS CTRL word Task 1
START/ STOP / HALT (with DBG11B only)
IPOS CTRL word Task 2
STOP / START (with DBG11B only)
Jerk time
0.005 ... 2 s
IPOS encoder
IPOS variables edit
ON / OFF (only in DBG11B)
Source actual position
Motor encoder (X15) / Ext. encoder (X14)
Encoder factor numerator
1 ... 32 767
Encoder factor denominator
1 ... 32 767
Encoder scaling ext. Encoder
x1 / x2 / x4 / x8 / x16 / x32 / x64
Synchronous encoder type (X14)
TTL / SIN/COS / HIPERFACE
Synchronous encoder counting
direction (X14)
NORMAL / INVERTED
Hiperface
®
Offset X14
–(2
31
–1) ... 0 ... 2
31
–1 inc.
IPOS Modulo function
Modulo function
OFF / SHORT / CW / CCW
Modulo numerator
0 ... 1 ... 2
31
– 1
Modulo denominator
0 ... 1 ... 2
31
– 1
Modulo encoder resolution
0 ... 4096 ... 65535
P6..
P60.
P600
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...
Page 432: ......