Overview of parameters
Parameters
Controller parameters
Speed control
P gain n controller
0.01 ... 2 ... 32
Time constant n-controller
0 ... 10 ... 3000 ms
Amplified acceleration feedfor-
ward
0 ... 65
Filter acceleration feedforward
0 ... 100 ms
Filter speed actual value
0 ... 32 ms
Load feedforward CFC
–150 ...0 ... 150 %
Sampling time n-controller
1 ms / 0.5 ms
Load feedforward VFC
–150 ... 0 ... 150 %
Hold controller
P gain hold controller
0.1 ... 0.5 ... 32
Synchronous operation control
Feedforward filter DRS
0 ... 100 ms
Synchronous operation with catch up
Synchronous speed
–5000 ... 1500 ... 5000 1/min
Synchronous ramp
0 ... 2 ... 50 s
Motor parameters
Limits 1 / 2
Start/stop speed 1 / 2
0 ... 150 1/min
Minimum speed 1 / 2
0 ... 15 ... 5500 1/min
Maximum speed 1 / 2
0 ... 1500 ... 5500 1/min
Current limit 1 / 2
0 ... 150 % I
N
Torque limit
0 ... 150 %
Motor compensation 1 / 2 (asynchronous)
Automatic adjustment 1/2
ON / OFF
Boost 1 / 2
0 ... 100 %
I
×
R compensation 1 / 2
0 ... 100 %
Premagnetizing time 1 / 2
0 ... 2 s
Slip compensation 1 / 2
0 ... 500 1/min
Motor protection
Motor protection 1 / 2
OFF / ON ASYNCHRONOUS / ON SERVO
Cooling type 1 / 2
FAN COOLED / FORCED COOLING
Interval for motor protection
0.1...4...20 s
Direction of rotation of the motor
Change direction of rotation 1 / 2
ON / OFF
Startup (only available in DBG60B)
Startup
YES / NO
Reference signals
Speed reference signal
Speed reference value
0 ... 1500 ... 5000 1/min
Hysteresis
0 ... 100 ... 500 1/min
Deceleration time
0 ... 1 ... 9 s
Signal = "1" if:
n < n
ref
/ n > n
ref
P6..
P60.
P600