Operating modes
Parameters
3.4
Operating modes
VFC 1 / 2
Default setting for asynchronous motors without encoder feedback. Suitable for general
applications, such as conveyor belts, trolleys, and hoists with counterweight. A flux-ori-
ented motor model is used. This model is optimally adapted to the motor after the startup
function in SHELL or in the DBG60B keypad has been carried out. It is necessary to en-
ter the motor type (SEW motor) or the nameplate data (motor from another manufactur-
er) as part of the startup function. The following parameters are preset (parameter set
1/2):
NOTE
For operating modes with encoder feedback, parameters must not be changed in
cycles faster than 2 seconds. This makes sure that the encoders can be initialized.
Settings after the startup function
P303 Current limit 1 / P313 Current limit 2
I
max
(inverter) = 150 % I
N_mot
P302 Maximum speed 1 / P312 Maximum speed 2
Depends on number of poles and rated
motor frequency
e. g. 2 pole / 50 Hz -> 3000 1/min
e. g. 4 pole / 60 Hz -> 1800 1/min
P301 Minimum speed 1 / P311 Minimum speed 2
15 1/min
P130 ... P133 Ramp t11 / P140 ... P143 Ramp t21
2 s
P136 Stop ramp t13 / P146 Stop ramp t23
2 s
P137 Emergency stop ramp t14 / P147 Emergency stop ramp
t24
2 s
P500 Speed monitoring 1 / P502 Speed monitoring 2
MOTOR & REGENERATIVE
P501 Deceleration time 1 / P503 Deceleration time 2
1 s
UNIPOL./FIX.SETPOINT
TERMINALS
P730 Brake function 1 / P733 Brake function 2
ON
P731 Brake release time 1 / P734 Brake release time 2
For SEW motors: Setting in accordance
with motor data.
For non-SEW motors: Set the correct
value manually!
P732 Brake application time 1 / 735 Brake application time 2
P300 Start/stop speed 1 / P310 Start/stop speed 2
15 1/min
P820 4-quadrant operation 1 / P821 4-quadrant operation 2
ON
P324 Slip compensation 1 / P334 Slip compensation 2
Setting in accordance with specified data
0
P322 IxR compensation 1 / P332 IxR compensation 2
Setting in accordance with specified data
P320 Automatic adjustment 1 / P330 Automatic adjustment 2
ON
P323 Premagnetizing time 1 / P333 Premagnetizing time 2
Setting in accordance with specified data
NOTES
•
SEW-EURODRIVE recommends using the P320 Automatic adjustment 1 / P330
Automatic adjustment 2 activated in the factory setting. The result is an automatic
setting during the pre-magnetization phase by calibrating the motor of P322 IxR
compensation 1 / P332 IxR compensation 2 .
•
SEW-EURODRIVE recommends keeping the parameters P321 Boost 1 / P331
Boost 2 at the factory setting (= 0).
P6..
P60.
P600