136
System Manual – MOVIDRIVE® compact Drive Inverters
3
Explanation of the parameters
Parameters
P41x Speed
window signal
Signals whether the speed is within or outside the set window range.
P410 Window
center
Setting range: 0 ... 1500 ... 5000 1/min
P411 Range width
Setting range: 0 ... 5000 1/min
P412 Deceleration
time
Setting range: 0 ... 1 ... 9 s
P413 Signal = “1“
when:
INSIDE / OUTSIDE
P42x Speed set-
point/actual value
comparison
Signal if the speed is equal to or not equal to the setpoint speed.
P420 Hysteresis
Setting range: 0 ... 100 ... 300 1/min
P421 Deceleration
time
Setting range: 0 ... 1 ... 9 s
P422 Signal = “1“
when:
n = n
setpt
/ n <> n
setpt
55733BEN
Figure 41: Speed window signal
t
1
1
0
0
P412
t
t
P411
n [1/min ]
P413: Signal = "1" at
n = n
Window
P413: Signal = "1" at n <> n
Window
P410
n
Window
01625BEN
Figure 42: Speed setpoint/actual value comparison
t
1
1
0
0
P421
t
t
P420
n [rpm]
n
setp
P422: Signal = "1" at n = n
setp
P422: Signal = "1" at n <> n
setp
P6..
P60.
P600