System Manual – MOVIDRIVE® compact Drive Inverters
47
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE® compact MC_4_A...-2_3 (AC 230 V units)
Technical Data and Dimension Drawings
Size 4
02573AXX
MOVIDRIVE
®
compact
0220-203-4-0_
0300-203-4-0_
INPUT
Supply voltage
V
mains
3
×
AC 200 V –10 % ... 3
×
AC 240 V +10 %
Supply frequency
f
mains
50 Hz ... 60 Hz
±
5 %
Rated mains current
I
mains
100 %
(when V
mains
= 3
×
AC 230 V) 125%
AC 72 A
AC 90 A
AC 86 A
AC 107 A
OUTPUT
Apparent output power
1)
S
N
(when V
mains
= 3
×
AC 230..0.240 V)
31.8 kVA
37.8 kVA
Rated output current
I
N
(when V
mains
= 3
×
AC 230 V)
AC 80 A
AC 95 A
Current limitation
I
max
Motor and regenerative 150 % I
N
, duration depending on the capacity utilization
Internal current limitation
I
max
= 0...150 % can be set in menu (P303 / P313)
Minimum permitted braking
R
BRmin
resistance value (4Q operation)
3
Ω
Output voltage
U
A
Max. V
mains
PWM frequency
f
PWM
Following values can be set: 4/8/12/16 kHz
Speed range / resolution
n
A
/
∆
n
A
–5500 ... 0 ... +5500 min
–1
/ 0.2 min
–1
across the entire range
GENERAL INFORMATION
Power loss at P
N
P
Vmax
1100 W
1300 W
Cooling air consumption
180 m
3
/h
Weight
26.3 kg
Dimensions
W
×
H
×
D
MCF/MCV/MCS:280
×
522
×
227 mm
MCH: 280
×
522
×
233 mm
1) The power data applies to f
PWM
= 4 kHz (factory setting for VFC operating modes).
P
i
f
kVA
Hz
n
Summary of Contents for MOVIDRIVE compact MCH41A
Page 2: ...SEW EURODRIVE Driving the world...
Page 432: ......