Installation

1

47

583
653
657

596
666
670

619
689
693

437

460 475

472

495 510

Instructions which must be followed by the drive and home automation professional installing the drive:

- Methods of wiring are given by national standards or IEC60364 standard.

- Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.

-  T5Hz02: The cable for the T5Hz02 can be removed. If it is damaged, replace by the same. The cable may only be 

connected to the motor by qualified  personnel. The connector is to be assembled without damaging the contacts. The 

continuity of the earth connection must be ensured.

-  T3.5Hz02 - T6Hz02: The cable for the T3.5Hz02 - T6Hz02 cannot be removed. If it is damaged, return the drive to the 

After-Sales department.

Recommendations:

- Keep a minimum distance of 

20 cm between two Hz.02 motors

.  

-  Keep a minimum distance of 

30 cm between Hz.02 motors and Hz transmitters

. A radio appliance using the same 

frequency (433,42MHz) may deteriorate our product’s performance (ex.: hi-fi radio headphones).

These instructions apply to all T3.5Hz02/T5Hz02/T6Hz02 drive, the different versions of which are available in the current 

catalogue. 

Field of application:

 T3.5Hz02/T5Hz02/T6Hz02 drive are designed to all types of roller shutters, outdoor awnings without 

cassette. The installer, who must be a motorisation and home automation professional, must ensure that the drive product 

is installed in accordance with the standards in force in the country in which it is installed such as EN 13659 relating to roller 

shutters, EN 13561 relating to outdoor screens and awnings. 

Liability:

 Before installing and using the drive, please read operating and installation guide carefully. 

Please read these 

instructions carefully

 before installing and using the drive. In addition to following the instructions given in this guide, the 

instructions detailed in the attached 

Safety instructions document

 must also be observed. The drive must be installed 

by a motorisation and home automation professional, according to instructions from SIMU and the regulations applicable 

in the country in which it is commissioned. It is prohibited to use the drive outside the field of application described above. 

Such use, and any failure to comply with the instructions given in this guide and in the attached 

Safety instructions 

document

, absolves SIMU of any liability and invalidates the warranty. The installer must inform its customers of the 

operating and maintenance conditions for the drive and must provide them with the instructions for use and maintenance, 

and the attached 

Safety instructions document

, after installing the drive. Any After-Sales Service operation on the drive 

must be performed by a motorisation and home automation professional. If in doubt when installing the drive, or to obtain 

additional information, contact a SIMU adviser or go to the website www.simu.com.

- Drilling of the tube:

1/5

5010945L

EN

Summary of Contents for T3.5Hz02

Page 1: ...utters outdoor awnings without cassette The installer who must be a motorisation and home automation professional must ensure that the drive product is installed in accordance with the standards in force in the country in which it is installed such as EN 13659 relating to roller shutters EN 13561 relating to outdoor screens and awnings Liability Before installing and using the drive please read op...

Page 2: ...ossibility to switch off individually each motor If the installation includes several motors only one motor is to be powered during this programming procedure It will eliminate interferences with the other motor during the procedure PE L N T3 5Hz02 PE L N T5Hz02 T6Hz02 230V 50 Hz 230V 50 Hz 1 1 5 channels Wall Hz transmitter Memory Hz 2 1 5 channels Mobile Hz transmitter 3 Color Multi 16 Timer Eas...

Page 3: ...irection 3 Before the motor reaches the UP end limit press the STOP key 1 Position the motor on the UP end limit using the UP and DOWN keys 2 To memorize the UP end limit position press simultaneously the STOP and DOWN keys The motor will run automatically in the DOWN direction 3 Before the motor reaches the DOWN end limit press the STOP key a b 4 1 Learning mode Switch the motor ON Simultaneously...

Page 4: ...he installation To delete an transmitter from the memory of a motor perform operations 6 1 with a programmed transmitter then perform the operation 6 2 with the transmitter to be deleted 4 5 1 Position the motor on the DOWN end limit previously set in 4 3a with the DOWN key 2 Press simultaneously for 5 seconds the UP and DOWN keys The motor will run for 0 5 second in one direction and then in the ...

Page 5: ...ly to the motor for 2 seconds 9 2 Switch the power to the motor back on for 7 seconds 9 3 Switch off the power supply to the motor for 2 seconds 9 4 Switch the power to the motor back on If the motor is on the end limit position up or down the motor will run briefly on one direction and then in the other otherwise the motor runs for 5 seconds in random direction The motor is now in the cancelling ...

Reviews: