Simu T3.5Hz02 Original Instructions Download Page 5

- This drive is maintenance-free.

- Press the 

▲ button on the control point to raise 

the motorised product.

 

- Press the

 ▼ button on the control point to lower 

the motorised product.

- If the motorised product is moving, briefly press the “STOP” button, the motorised product stop automatically.

-  The motorised product is then stopped, briefly press the “STOP” button, the motorised product moves to the 

programmed intermediate position. (To modify or delete an intermediate position, see the section §7).

Tips and recommendations for use:

If the motorised product still does not work, contact a drive and home automation professional.

5/5

SIMU SAS, F-70103 GRAY as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz 

and used as intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives and in  

particular of the Machinery Directive 2006/42/EC, and the Radio Directive 2014/53/EU. The full text of the EU declaration of conformity is available at  

www.simu.com. Emmanuel CARMIER, general director, GRAY, 12/2016.

9.1- Switch off the power supply to the motor for 

2 seconds

.

9.2- Switch the power to the motor back on for 

7 seconds

.

9.3- Switch off the power supply to the motor for 

2 seconds

.

9.4- Switch the power to the motor back on.

-  If the motor is on the end limit position (up or down), the 

motor will run briefly on one direction and then in the 

other, otherwise, the motor runs for 5 seconds in random 

direction. The motor is now in the "cancelling" mode.

Cancelling programming and settings

9

Operation and maintenance

10

9.5- Then, validate the cancelling of the affected motor from the individual control:

If you switch off the power to several motors, they will all be in cancelling mode. That is why, you must 

"eject" out of this mode all the motors that are not to be deleted by sending a command from their 

individual control transmitter (UP or Down).

-  Press the PROG key of the transmitter 

more than 7 

seconds

. Maintain the pressure until the motor will first 

run for 0,5 second in one direction and then the other, 

and a few second later, it will run again in both direction.

The Hz02 motor is now as it was originally configured, and no transmitter and no settings is saved in its memory and is 

ready for a new programming.

>

Problems

Possible causes

Solutions

The motorised product does not operate. The overheating protection on the drive has been activated.

Wait for the drive to cool down.

EN

Summary of Contents for T3.5Hz02

Page 1: ...utters outdoor awnings without cassette The installer who must be a motorisation and home automation professional must ensure that the drive product is installed in accordance with the standards in force in the country in which it is installed such as EN 13659 relating to roller shutters EN 13561 relating to outdoor screens and awnings Liability Before installing and using the drive please read op...

Page 2: ...ossibility to switch off individually each motor If the installation includes several motors only one motor is to be powered during this programming procedure It will eliminate interferences with the other motor during the procedure PE L N T3 5Hz02 PE L N T5Hz02 T6Hz02 230V 50 Hz 230V 50 Hz 1 1 5 channels Wall Hz transmitter Memory Hz 2 1 5 channels Mobile Hz transmitter 3 Color Multi 16 Timer Eas...

Page 3: ...irection 3 Before the motor reaches the UP end limit press the STOP key 1 Position the motor on the UP end limit using the UP and DOWN keys 2 To memorize the UP end limit position press simultaneously the STOP and DOWN keys The motor will run automatically in the DOWN direction 3 Before the motor reaches the DOWN end limit press the STOP key a b 4 1 Learning mode Switch the motor ON Simultaneously...

Page 4: ...he installation To delete an transmitter from the memory of a motor perform operations 6 1 with a programmed transmitter then perform the operation 6 2 with the transmitter to be deleted 4 5 1 Position the motor on the DOWN end limit previously set in 4 3a with the DOWN key 2 Press simultaneously for 5 seconds the UP and DOWN keys The motor will run for 0 5 second in one direction and then in the ...

Page 5: ...ly to the motor for 2 seconds 9 2 Switch the power to the motor back on for 7 seconds 9 3 Switch off the power supply to the motor for 2 seconds 9 4 Switch the power to the motor back on If the motor is on the end limit position up or down the motor will run briefly on one direction and then in the other otherwise the motor runs for 5 seconds in random direction The motor is now in the cancelling ...

Reviews: