1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
135
User Manual 1173.9511.02 ─ 11
See also: "Retrieving Measurement Results" in the R&S
CMW user manual, chapter
"Remote Control"
2.6.1.2
Keywords
Selected keywords used in the command description are described in the following.
●
Command usage
If the usage is not explicitly stated, the command allows you to set parameters and
query parameters. Otherwise the command usage is stated as follows:
–
"Setting only": command can only be used to set parameters
–
"Query only": command can only be used to query parameters
–
"Event": command initiates an event
●
Parameter usage
The parameter usage is indicated by the keyword preceding the parameter(s):
–
"Parameters" are sent with a setting or query command and are returned as
the result of a query
–
"Setting parameters" are only sent with a setting command
–
"Query parameters" are only sent with a query command (to refine the query)
–
"Return values" are only returned as the result of a query
●
Firmware/Software:
Indicates the lowest software version supporting the command. Command
enhancements in later software versions are also indicated.
2.6.1.3
Reliability Indicator
The reliability indicator has one of the following values:
●
0 (OK)
:
Measurement values available, no error detected.
●
1 (Measurement Timeout)
:
The measurement has been stopped after the (configurable) measurement time-
out. Measurement results may be available, however, at least a part of the mea-
surement provides only INValid results or has not completed the full statistic count.
●
2 (Capture Buffer Overflow)
:
The measurement configuration results in a capture length, exceeding the availa-
ble memory.
●
3 (Overdriven) / 4 (Underdriven)
:
The accuracy of measurement results may be impaired because the input signal
level was too high / too low.
●
6 (Trigger Timeout)
:
The measurement could not be started or continued because no trigger event was
detected.
●
7 (Acquisition Error)
:
The R&S
CMW could not properly decode the RF input signal.
●
8 (Sync Error)
:
The R&S
CMW could not synchronize to the RF input signal.
Command Reference