1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
138
User Manual 1173.9511.02 ─ 11
In the 1xEV-DO signaling application, reliability indicators are returned with RX mea-
surement results - for the following more specific reasons:
Reliability Indicator
Reason
6
A Test Application report was not received from the mobile within 3 update
time periods.
19
Not in connected state.
103
●
The 1xEVDO signaling Test Application is not enabled
●
Forward Link measurement data were requested, but the Test Applica-
tion direction is not set to "Forward" or "Forward & Reverse"
●
Reverse Link measurement data were requested, but the Test Applica-
tion direction is not set to "Reverse" or "Forward & Reverse"
●
Measurement data were requested, but the corresponding measure-
ment is not assigned
2.6.2 Cell and Connection State
The following commands are related to the connection to the AT under test.
..................................................................................... 138
SOURce:EVDO:SIGN<i>:STATe:ALL?
.............................................................................139
CALL:EVDO:SIGN<i>:CSWitched:ACTion
........................................................................139
FETCh:EVDO:SIGN<i>:CSWitched:STATe?
.....................................................................140
FETCh:EVDO:SIGN<i>:PDATa:STATe?
.......................................................................... 140
CONFigure:EVDO:SIGN<i>:CSTatus:PLSubtype?
............................................................ 140
CONFigure:EVDO:SIGN<i>:CSTatus:IRAT?
.....................................................................141
CONFigure:EVDO:SIGN<i>:CSTatus:APPLication?
...........................................................141
CONFigure:EVDO:SIGN<i>:CSTatus:MODE?
...................................................................141
CONFigure:EVDO:SIGN<i>:CSTatus:AFLCarriers?
...........................................................142
CONFigure:EVDO:SIGN<i>:CSTatus:ARLCarriers?
.......................................................... 142
CONFigure:EVDO:SIGN<i>:CSTatus:LOG?
..................................................................... 143
SOURce:EVDO:SIGN<i>:STATe
<Control>
Turns the 1xEV-DO Signaling generator (the cell) off or on.
Setting parameters:
<Control>
ON | OFF
Switch generator
ON
or
OFF
*RST:
OFF
Return values:
<GeneratorState>
OFF | PENDing | ON
OFF:
generator switched off
PEND:
generator switched on but no signal available yet
ON:
generator switched on, signal available
*RST:
OFF
Example:
See
Firmware/Software:
V1.0.15.0
Command Reference