1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
235
User Manual 1173.9511.02 ─ 11
Condition
Status String
No problem detected
OK
No forward test application run-
ning
Reverse Test Application Off
No results
Connect call with Reverse Test Application
AT not connected
No call connected
No results
Connect call with Reverse Test Application
Timeout (internal)
Timeout waiting for RPER reports
No results
Restart signaling task
FETCh:EVDO:SIGN<i>:RXQuality:RLPer:CSTate?
FETCh:EVDO:SIGN<i>:RXQuality:RLPFormance:CSTate?
Returns status information about the carrier.
Return values:
<Reliability>
See
<CarrierStatus>
OK | VIOLated | STALe | INACtive
Example:
See
Perform Reverse Link Measurements
Usage:
Query only
Firmware/Software:
V3.0.10
V3.2.20: command renamed
Options:
R&S CMW-KS890 required for throughput measurements
2.6.11.9
Data Results
This section provides the results of the end-to-end data measurements.
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:RESet?
.....................................................235
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:RACK?
..................................................... 236
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:NAK?
....................................................... 237
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:SUMMary?
................................................237
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:PPPTotal?
................................................ 238
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:DRATe?
................................................... 238
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:STATe?
.................................................... 238
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:RESet?
Number of packets associated with RLP Reset messages, which are sent between AT
and AN to reset RLP.