CDMA2000 Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
775
User Manual 1173.9511.02 ─ 11
FETCh:CDMA:MEAS:MEValuation:LIST:CPO:RSCH:ZTEF:STATe?
FETCh:CDMA:MEAS:MEValuation:LIST:CTO:RCCCh:STATe?
FETCh:CDMA:MEAS:MEValuation:LIST:CTO:RDCCh:STATe?
FETCh:CDMA:MEAS:MEValuation:LIST:CTO:REACh:STATe?
FETCh:CDMA:MEAS:MEValuation:LIST:CTO:RFCH:STATe?
FETCh:CDMA:MEAS:MEValuation:LIST:CTO:RPICh:STATe?
FETCh:CDMA:MEAS:MEValuation:LIST:CTO:RSCH:ZOET:STATe?
FETCh:CDMA:MEAS:MEValuation:LIST:CTO:RSCH:ZTEF:STATe?
FETCh:CDMA:MEAS:MEValuation:LIST:SRELiability?
5.5 Command Reference
The following sections provide detailed reference information on the remote control
commands of the "CDMA2000 Measurements" application.
Conventions and General Information
.................................................................. 775
............................................................................ 779
Multi Evaluation Measurement Commands
.......................................................... 789
.......................................................................... 900
.......................................................................909
5.5.1 Conventions and General Information
The following sections describe the most important conventions and general informa-
tion concerning the command reference.
5.5.1.1
MEAS<i>
MEAS<i> is used as abbreviation of "MEASurement<instance>". For better readability
only the abbreviated form (which is also accepted by the instrument) is given in the
command reference.
The <instance> is relevant for instruments supporting several instances of the same
firmware application. It can be omitted if the instrument supports only one instance, or
to address the first instance.
See also: "Firmware Applications" in the R&S
CMW user manual, chapter "Remote
Control"
5.5.1.2
FETCh, READ and CALCulate Commands
All commands are used to retrieve measurement results:
●
FETCh...
returns the results of the current measurement cycle (single-shot mea-
surement) after they are valid.
FETCh...
must be used after the measurement
has been started (
INITiate...
, measurement states RUN or RDY).