CDMA2000 Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
779
User Manual 1173.9511.02 ─ 11
Indicates a firmware or software error. If you encounter this error for the first time,
restart the instrument.
If the error occurs again, consider the following hints:
–
Firmware errors can often be repaired by restoring the factory default settings.
To restore these settings, restart your instrument and press the "Factory
Default" softkey during startup.
–
If a software package (update) has not been properly installed this is often indi-
cated in the "Setup" dialog, section "SW/HW-Equipment > Installed Software".
–
A software update correcting the error may be available. Updates are e.g. pro-
vided in the "CMW Customer Web" on GLORIS (registration required):
.
If you get firmware errors even with the properly installed latest software version,
please send a problem report including log files to Rohde & Schwarz.
●
102 (Unidentified Error)
:
Indicates an error not covered by other reliability values. For troubleshooting
please follow the steps described for "101 (Firmware Error)".
●
103 (Parameter Error)
:
Indicates that the measurement could not be performed due to internal conflicting
parameter settings.
A good approach to localize the conflicting settings is to start with a reset or preset
or even restore the factory default settings. Then reconfigure the measurement
step by step and check when the error occurs for the first time.
If you need assistance to localize the conflicting parameter settings, please contact
Rohde & Schwarz (see
http://www.service.rohde-schwarz.com
5.5.2 General Measurement Settings
The commands valid for all CDMA2000 TX measurements are divided into the groups
listed below.
5.5.2.1
Signal Routing
The following commands configure the scenario, select the connector and define an
external attenuation value.
.............................................................................................. 779
............................................................................... 780
ROUTe:CDMA:MEAS<i>:SCENario:SALone
.....................................................................780
ROUTe:CDMA:MEAS<i>:SCENario:CSPath
.....................................................................781
ROUTe:CDMA:MEAS<i>:SCENario:CATalog:CSPath?
......................................................781
CONFigure:CDMA:MEAS<i>:RFSettings:EATTenuation
.................................................... 782
ROUTe:CDMA:MEAS<i>?
Returns the configured routing settings.