The RF frequency settings can be changed in all main connection states. Changing the
RF frequency via this section causes an implicit channel handoff. Use the "Handoff"
dialog to perform a standard handoff (see
Remote command:
Frequency Offset
Modifies the nominal forward link frequency of the selected band class and RF chan-
nel. A frequency offset represents a signal impairment; it can be as well to simulate a
moving AT, causing a Doppler shift of the received RF signal.
Remote command:
2.4.7.4
RF Power
Fig. 2-28: 1xEV-DO RF power settings
............................................................................................... 72
..............................................................................................73
1xEV-DO Power
Absolute power of the main carrier's forward 1xEV-DO signal, excluding a possible
AWGN contribution.
Remote command: