1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
373
User Manual 1173.9511.02 ─ 11
CALCulate:EVDO:MEAS<i>:MEValuation:CP:CURRent?
CALCulate:EVDO:MEAS<i>:MEValuation:CP:AVERage?
CALCulate:EVDO:MEAS<i>:MEValuation:CP:MAXimum?
CALCulate:EVDO:MEAS<i>:MEValuation:CP:MINimum?
FETCh:EVDO:MEAS<i>:MEValuation:CP:AVERage?
FETCh:EVDO:MEAS<i>:MEValuation:CP:CURRent?
FETCh:EVDO:MEAS<i>:MEValuation:CP:MAXimum?
FETCh:EVDO:MEAS<i>:MEValuation:CP:MINimum?
READ:EVDO:MEAS<i>:MEValuation:CP:CURRent?
READ:EVDO:MEAS<i>:MEValuation:CP:AVERage?
READ:EVDO:MEAS<i>:MEValuation:CP:MAXimum?
READ:EVDO:MEAS<i>:MEValuation:CP:MINimum?
Returns the scalar channel power for the Data channel. The result is extended to the
W
2
4
and W
1
2
I/Q values of the Data channel. Only available if subtype 2 or 3 is
selected. Otherwise
NAV
is returned.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Return values:
<Reliability>
<W24IData>,
<W24QData>,
<W12IData>,
<W12QData>
W
2
4
- I Data channel,
W
2
4
- Q Data channel,
W
1
2
- I Data channel,
W
1
2
- Q Data channel
Range:
-60 dB to +10 dB
Default unit: dB
Example:
See
Multi Evaluation: Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V2.0.10
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
3.5.4.17
Spectrum (Traces)
The following commands return the results of the spectrum multi evaluation measure-
ment.
FETCh:EVDO:MEAS<i>:MEValuation:TRACe:SPECtrum:CURRent?
READ:EVDO:MEAS<i>:MEValuation:TRACe:SPECtrum:CURRent?
Returns the power spectrum traces across the frequency span (8 MHz or 16 MHz for
single-carrier configurations, 16 MHz for multi-carrier configurations; see
).
Return values:
<Reliability>
Command Reference