CDMA2000 Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
801
User Manual 1173.9511.02 ─ 11
Suffix:
<no>
.
1..200
The segment number must not exceed the total number of seg-
ments measured.
Parameters:
<SegmentLength>
Number of measured Power Control Groups (slots) in the seg-
ment.
The sum of the segment lengths must not exceed 10000 slots;
limit violation is indicated by a reliability indicator of 2 (Capture
Buffer Overflow).
Range:
1 to 1000
*RST:
1
<Level>
Expected nominal power in the segment. The range of the
expected nominal power can be calculated as follows:
Range (Expected Nominal Power) = Range (Input Power) +
External Attenuation - User Margin
Range:
Range: –120 dBm to 50 dBm for the input power at
RF 1 COM and RF 2 COM (please notice also the
ranges quoted in the data sheet)
*RST:
0 dBm
<Frequency>
Center frequency of the RF analyzer.
Range:
100E+6 Hz to 6E+9 Hz
*RST:
833.49E+6 Hz
Default unit: Hz
<RetriggerOption>
OFF | ON
Enables or disables the trigger system to start segment mea-
surement.
Note:
For the first segment (
<no>
= 1) the setting of this param-
eter is ignored. Since the general MELM measurement starts
with the measurement of the first segment. That mean always
with the first trigger event the first segment is measured.
OFF
: Disabled retrigger. The segment measurement is started
by the first trigger event.
ON
: Enables the retrigger. The list mode measurement contin-
ues only if a new event for this segment is triggered (retrigger).
*RST:
OFF